Skip to content

SU type drying units are used for small farms and large grain elevators.

They can operate in continuous and interval modes. Their universal design makes them suitable for drying rape, consumption and feed grain, corn, buckwheat, malting barley, seeds, legumes and sunflower

Suszarnie_Uniwersalne_typu_SU_92z
Suszarnie_Uniwersalne_typu_SU_31r
SAM_0694_1
DSCF6361_1

Thanks to the modular structure of the dryer column it can be expanded. The system of grain flowing through two transfer columns ensures that the drying is even. The hot air chamber (middle) is located in the centre of the column, between transfer section. This minimises heat losses and ensures optimal flow of the air stream through the dried grain. The collection system is equipped with double performance regulation (mechanical and electronic). It optimises the operation of the unit by taking into account the type of dried grain, moisture content, temperature of the drying medium and the purpose of the grain.

Heating oven – the heat exchanger made of high quality acid and heat resistant steel ensures the isolation of flue gases from the drying air (grain has no contact with fuel combustion products). This ensures that EU and HACCP standards for consumption materials are met.

Control cabinet – Modern, PLC-controlled power cabinets made by AGREMO ensure accurate and optimal operation of the drying unit and auxiliary systems. The input operation parameters are continuously monitored by the system which ensures their stability and operational safety.

Optional:

oven fired with biomass (e.g. straw)

natural gas or LPG (propane) burner

air collector insulation

expanding the cabinet for the purposes of being controlled by other devices

devices for charging and collecting the materials from the drying unit

buffer tanks for wet grain

TECHNICAL PARAMETERS
SU-3
SU-5
SU-7
SU-10
SU-13
SU-15
SU-20
Grain – moisture reduction from 19% to 15%
Capacity (T/h) 3 5 7 10 13 15 20
Daily capacity 72 120 168 240 312 360 480
Rape – moisture reduction from 13% to 7%
Capacity (T/h) 2,0 3,1 4,4 5,3 6,2 7,1 9,2
Daily capacity 48 76 105 127 149 170 220
Corn – moisture reduction from 30% to 15%
Capacity (T/h) 0,8 1,3 1,8 2,5 3,5 4,1 4,6
Daily capacity 19 31 43 60 84 98 110
Heating power (kW) 294 485 593 830 830 1186 1540
Electrical power (kW) 10,9 12,2 17,8 18,4 22,4 24 29
Charge capacity (m3) 12,1 13,5 17,8 22,2 24,2 28,2 36,2
Charge capacity (t) for 0.75 t/m3 9,0 10,1 13,3 16,6 18,1 21,1 27,1
Size of the column incl. oven (m)
Length 4,3 4,9 5,1 5,7 5,7 6,0 7,0
Width 3,2 3,2 3,2 3,4 4,2 4,2 5,3
Height 7,5 8,1 9,9 9,3 9,9 11,1 13,5
Download brochure in PDF